-40%

NEW - SMART500RT1U

$ 79.2

Availability: 100 in stock
  • Backup Time: 3 min full load, 14 min 1/2 load
  • Item must be returned within: 60 Days
  • Return shipping will be paid by: Seller
  • Output Voltage Rating (AC): 120V
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Brand: Tripp Lite
  • Number of Outputs: 5
  • All returns accepted: Returns Accepted
  • Maximum Operating Temperature: +104 Deg F
  • Condition: New
  • Mounting Style: 19" Rack Mount
  • Installation Area: Indoor
  • Nominal Voltage Rating (AC): 120V
  • Nominal Capacity: 500 VA, 300 Watt
  • Output Voltage Rating (DC): 120V
  • Minimum Operating Temperature: +32 Deg F
  • MPN: SMART500RT1U

    Description

    New - Unopened box.
    Tripp-Lite SMART500RT1U UPS Battery Backup - 1U
    1U rack-mount UPS offers co
    mplete
    power protection for small network applications, including telecom, security and digital signage.
    Protects equipment against blackouts, brownouts, transient surges and line noise
    Keeps AC power running during blackouts to allow time for file saves and safe shutdown
    Maintains continuous 120V nominal output during brownouts as low as 90V
    6 NEMA 5-15R outlets power and protect networking, telecom and other sensitive equipment
    Optional WEBCARDLX network interface allows you 24/7 remote access from anywhere
    Specifications
    OVERVIEW
    UPC Code
    037332119247
    UPS Type
    Line-Interactive
    INPUT
    Nominal Input Voltage(s) Supported
    120V AC
    UPS Input Connection Type
    5-15P
    Input Circuit Breakers
    10A
    UPS Input Cord Length (ft.)
    10
    Recommended Electrical Service
    15A 120V
    Input Phase
    Single-Phase
    OUTPUT
    Output Volt Amp Capacity (VA)
    500
    Output Watt Capacity (Watts)
    300
    Frequency Compatibility
    60 Hz
    Output Voltage Regulation (Line Mode)
    -14%, +16%
    Output Voltage Regulation (Battery Mode)
    +/- 5%
    UPS Output Receptacles (Surge Suppression Only)
    5 UPS outlets, 1 surge-only outlet
    Load Management Receptacles
    One switchable single-outlet 5-15R load bank
    Output AC Waveform (AC Mode)
    Sine wave
    Output AC Waveform (Battery Mode)
    PWM sine wave
    Nominal Output Voltage(s) Supported
    120V
    Output Receptacles
    (6) 5-15R
    Individually Controllable Load Banks
    Yes
    BATTERY
    Battery Type
    Valve Regulated Lead Acid (VRLA)
    Full Load Runtime (min.)
    3 min. (300w)
    Half Load Runtime (min.)
    14 min. (150w)
    Expandable Runtime
    No
    DC System Voltage (VDC)
    12
    Battery Recharge Rate (Included Batteries)
    Less than 12 hours to 90%
    Battery Access
    Battery access door
    Internal UPS Replacement Battery Cartridge
    IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite
    RBC62-1U
    replacement battery; Contact Tripp Lite customer service for additional information
    Battery Replacement Description
    Hot-swappable, user replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation Description
    Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 (±5%)
    Undervoltage Correction
    Input voltages between 90 and 105 (±5%) are boosted by 14%
    USER INTERFACE, ALERTS & CONTROLS
    Switches
    2 Switches control off/on power status and alarm-cancel/self-test operation
    Alarm Cancel Operation
    Power-fail alarm can be silenced using alarm-cancel switch
    Audible Alarm
    Audible alarm indicates power-failure, overload and low-battery conditions
    LED Indicators
    5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
    SURGE / NOISE SUPPRESSION
    EMI / RFI AC Noise Suppression
    Yes
    AC Suppression Joule Rating
    567
    AC Suppression Response Time
    Instantaneous
    PHYSICAL
    Primary Form Factor
    Rackmount
    Included Mounting Accessory Description
    Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations
    Installation Form Factors Supported with Included Accessories
    2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower
    Minimum Required Rack Depth (inches)
    14.3
    Primary UPS Depth (mm)
    286
    Primary UPS Height (mm)
    44
    Primary UPS Width (mm)
    440
    Rack Height
    1U
    Shipping Dimensions (hwd / in.)
    4.20 x 15.70 x 21.30
    Shipping Weight (lbs.)
    19.12
    UPS Housing Material
    Steel
    UPS Power Module Dimensions (hwd, in.)
    1.73 x 17.32 x 11.26
    UPS Power Module Weight (kg)
    7.18
    UPS Power Module Weight (lbs.)
    15.84
    ENVIRONMENTAL
    Operating Temperature Range
    +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    Storage Temperature Range
    +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    Relative Humidity
    0 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)
    48
    AC Mode Efficiency Rating (100% Load)
    97%
    Audible Noise
    45 dBA maximum, front side 1m
    COMMUNICATIONS
    Network Management Cards
    WEBCARDLX
    Network Monitoring Port Description
    Supports detailed monitoring of UPS and site power conditions
    PowerAlert Software
    For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
    Communications Cable
    USB and DB9 cabling included
    WatchDog Compatibility
    Supports Watchdog application, OS and hard-reboot restart options for remote applications
    Communications Interface
    DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
    LINE / BATTERY TRANSFER
    Transfer Time
    4-6 ms typical ( < 10 ms max)
    Low Voltage Transfer to Battery Power (Setpoint)
    90
    High Voltage Transfer to Battery Power (Setpoint)
    139
    SPECIAL FEATURES
    Grounding Lug
    Back panel grounding lug
    Cold Start (Startup in Battery Mode During a Power Failure)
    Cold-start operation supported
    High Availability UPS Features
    Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
    STANDARDS & COMPLIANCE
    UPS Certifications
    ENERGY STAR Qualified; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
    Certification Details
    Series Number AG-03AA; Safety Standards (Canada) CAN/CSA-C22.2 No. 107.3-14 (3rd Ed); Safety Standards (U.S.) UL1778:2014 (5th Ed) R10.17; FCC/ICES Compliant CLASS A; 47 CFR FCC PART 15 SUBPART B; ICES-003:2016