Vertiv Liebert EXM 180 kVA Model 47SA180SAC001RJ

$ 24288

Availability: 100 in stock
  • Condition: Excellent condition - tested prior to shipment
  • Output Voltage Rating (AC): 208V
  • All returns accepted: ReturnsNotAccepted
  • Nominal Voltage Rating (AC): 208V
  • Type: Online/Double-Conversion UPS
  • Nominal Capacity: 180KW
  • Brand: Liebert

    Description

    Liebert EXM Single Module UPS System each consisting of the following: 180kVA
    Nameplate Liebert EXM UPS, model 47SA180SAC001RJ, with the following features:
    • System Input Voltage of 208/120V, 3 Phase, 4 wire plus ground
    • System Output Voltage of 208/120V, 3 Phase, 4 wire plus ground
    • Fixed Capacity 180kVA UPS System
    • 208V Native Output Voltage
    • Single Input Configuration
    • One (1) IntelliSlot Unity Dual Protocol Card; P/N: IS-UNITY-DP; Monitoring and
    configuration of Vertiv products and environmental sensors through stand-alone Web UI
    or integration with Trellis™, Liebert Nform, LIFE™ Services. Supports third-party
    management systems using SNMP, Modbus or BACnet.
    • Transformer-Free Architecture - Efficiency up to 95% in double conversion mode
    • Unity Power Factor Rating - Delivers more usable power per kVA
    • Load Power Factor Support - Supports loads 0.5 lagging to unity without derating
    • Energy Optimization Mode (Eco-Mode)
    • 65kAIC Rating - Provides interrupting rating and labeling of 65kA
    • Active Power Factor Corrected IGBT Input Converter
    • PWM transistorized (IGBT) inverter
    • Continuous Duty Static Bypass Switch
    • Input Contacts - Dry contacts are available for functions including monitoring external
    breakers, on-generator signal, and other functions
    • Output Contacts - Dry contacts are available for functions including a permissive signal
    to maintenance bypass SKRU, to trip external breakers, and other functions
    • Generator Load Control - Suppresses battery charging reducing power demand by an
    external signal. Shifts unit from Eco Mode to double conversion (if applicable), and
    synchronizes the inverter output with the bypass
    • Automatic retransfer - Provides return to inverter power after an overload
    • DSP based controls - Provides digital control of power conversion and system operation
    • Backlit LCD display - Monitors power conversion, UPS operation and utility conditions.
    Deviations are logged for troubleshooting
    • Temperature-Compensated Charging/Battery Load Test
    • Top-and-bottom-entry cable access
    • Front only service access
    • Local Emergency Power Off (EPO)
    • LIFE™ Services for the 1st year
    • IP 20 enclosure
    • Casters and leveling feet
    • UL and cUL Listed to UL Standard 1778 4th Edition
    Vertive Battery solution consisting of the following :
    • 6 min @ 180 kVA, (2) -880 MM External Cabinet(s) of ENERSYS HX400-FR Batteries
    per UPS module
    • 6 min: Run Time at Ordered KVA
    • BP-No Battery Monitoring
    • Cabinet Mounted Left Attached to Module
    The solution includes
    Maintenance Bypass Cabinet, model 47MBS38CC0R1074
    with the following features:
    • 3 Switching Devices (BIB,MBB,MIB)
    • 800 Amp Breaker Trip Rating
    • Key Interlock (SKRU)
    • Cabinet Mounted Right Attached to Module with connecting cables factory supplied
    • 800 MM - 31.5 inches Frame Size
    • Front Access service design